Logon Security and Escalating Lockout Mechanism |
|
|
The logon security regime utilizes a structured lock-up mechanism designed to protect the device from unauthorized access through brute-force attempts. This system incorporates escalating grace periods following unsuccessful login attempts to balance security with operational recovery.
Security Access Thresholds and Penalty Phases
|
Cumulative Failed Attempts |
Penalty Phase / Action |
Duration |
3 |
Initial Grace Period |
20 Minutes |
6 |
Intermediate Grace Period |
60 Minutes |
9 |
Extended Grace Period |
24 Hours |
12 |
Device Locked |
Permanent (Requires Recovery) |
Access Method |
Grace Period Active (Fail) |
Device Locked (Lock) |
Physical Cable |
Fault Code 156 |
Fault Code 158 |
Remote Connection |
Fault Code 157 |
Fault Code 159 |
In all instances, a code 156 or 157 implies that the escalating grace period mechanism is active, requiring a specific wait time before the next logon attempt can be made. A code 158 or 159 indicates that the maximum number of attempts has been exceeded and the device is locked for further attempts.
•Programmatic Reset: The password can be cleared from within the application at any time by calling the boardSetPassword() function.
•Manufacturer Key: You can request a "clear password key" directly from Logic IO.
How to apply the Clear Password Key:
1.Open the RTCU M2M Studio.
2.Navigate to [Device] → [Maintenance] → [Apply Option Key].
3.Enter the provided key.