netGetMobileParam (Functionblock)

Top  Previous  Next

Architecture:

X32 / NX32 / NX32L

Firmware version:

4.34 / 1.00.00


netGetMobileParam will read out the TCP/IP parameters previously set from the RTCU M2M Studio or by the netSetMobileParam or sockSetTCPIPParm functions.

 

The format of an IP address is the same as returned by the sockGetLocalIP function.

 

Input:

None.

 

Output:

IP : DINT

The IP address of the device.

 

SubnetMask : DINT

The Subnet mask of the device.

 

Gateway : DINT

The TCP/IP gateway the device uses.

 

DNS1 : DINT

The first Domain Name Server the device uses to look up symbolic names.

 

DNS2 : DINT

The second Domain Name Server the device uses to look up symbolic names.

 

Authenticate : INT

The PPP authentication type:

0 = None.

1 = PAP.

2 = CHAP.

3 = PAP/CHAP.

 

Username : STRING

The user name the device uses in order to connect to the mobile network.

 

Password : STRING

The password the device uses in order to connect to the mobile network.

 

APN : STRING

The APN the device uses in order to connect to the mobile network.

 

 

Declaration:

FUNCTION_BLOCK netGetMobileParam;
VAR_OUTPUT
   IP             : DINT;
   SubnetMask     : DINT;
   Gateway        : DINT;
   DNS1           : DINT;
   DNS2           : DINT;
   Username       : STRING;
   Password       : STRING;
   APN            : STRING;
   Authenticate   : INT;
END_VAR;

 

Example:

INCLUDE rtcu.inc
 
PROGRAM test;
VAR
   mobileParam  : netGetMobileParam;
END_VAR;
 
mobileParam();
IF NOT (mobileParam.IP = 0 AND mobileParam.SubnetMask = 0 AND mobileParam.Gateway = 0 AND
   mobileParam.DNS1 = 0 AND mobileParam.DNS2 = 0 AND mobileParam.Authenticate = AND
   mobileParam.Username = "" AND mobileParam.Password = "" AND mobileParam.APN = "internet") THEN
   // Set APN and keep the default values for the others
   netSetMobileParam(APN := "internet");
END_IF;
 
// Turn on power to the GSM module
gsmPower(power := ON);
netOpen(iface := 1);
BEGIN
 
  // ...
 
END;
 